| MLC 62 RS CC |
|
| General |
| Power supply | External, included
Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 0.5 A, 6 watts |
| Power input requirements | 12 VDC |
| Power consumption | |
| MLC 62 RS models | |
| Device | 2.1 watts |
| Device and power supply | 2.5 watts |
| Cooling | Convection |
| Thermal dissipation | |
| MLC 62 RS models | |
| Device | 7.0 BTU/hr |
| Device and power supply | 8.4 BTU/hr |
| Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
| Mounting | Mounts into Cable Cubby® 1202 and 1402 enclosures |
| Material | Metal |
| Dimensions | 4.2" W x 2.4" D x 3.9" H
(107 mm W x 61 mm D x 100 mm H) |
| |  |
| Product weight | 1.0 lb (0.5 kg) |
| Vibration | ISTA 1A in carton (International Safe Transit Association) |
| Regulatory compliance | CE, c-UL, UL, C-tick, FCC Class A, ICES, VCCI Class A, RoHS, WEEE
Section 508 of the Rehabilitation Act (29 U.S.C. 794d) |
| Product warranty | 3 years parts and labor |
| Everlast power supply warranty | 7 years parts and labor |
|
| Control — host ports |
| Serial control port | 1 bidirectional RS-232 on a 3.5 mm captive screw connector, 3 pole |
| Baud rate and protocol | 9600 baud, 8 data bits, 1 stop bit, no parity |
| Serial control pin configuration | Pin 1 = Tx, pin 2 = Rx, pin 3 = GND |
| USB control ports | 1 side panel female mini USB B |
| USB standards | USB 2.0, low speed |
| IR learning frequencies | 30 kHz to 60 kHz |
| IR learning distance | 4" (10 cm) to 14" (36 cm) from the receiver (on side panel) |
| Program control | Extron configuration program for Windows® Extron Simple Instruction Set (SIS™) |
|
| Serial control |
| Display control port | (1) 3.5 mm captive screw connector, 2 pole for unidirectional RS-232 control (±5 V) |
| Baud rate and protocol (RS-232) | 9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits; 1 stop bit; no parity (default), or even or odd parity |
|
| IR control |
| IR control port | (1) 3.5 mm captive screw connector, 2 pole (transmit only)
TTL level (0 to 5 V) modulated infrared control from 30 kHz up to 60 kHz, or ±5 V
RS-232 control
*IR/serial ports are configurable via software, serial communication is the default. |
| Baud rate and protocol | 9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits; 1 stop bit; no parity (default), or even or odd parity |
|
| Relay control |
| Number/type | 2 momentary or latching (configurable via software) |
| Connector | (1) 3.5 mm captive screw connector, 3 pole
|
| Contact rating | 24 V, 1 A |
|
| Digital input control |
| Number/type | 1 digital input (configurable) |
| Connector | (1) 3.5 mm captive screw connector, 2 pole
|
| Digital inputs | |
| Input voltage range | 0-24 VDC |
| Input impedance | 12k ohms |
| Programmable pullup | 2k ohms to +5 VDC |
| Threshold low to high | >1.5 VDC |
| Threshold high to low | <1.0 VDC |
| NOTE | All nominal levels are at ±10%. |
|
| NOTE | Specifications are subject to change without notice. |
|
| (4514-D2) |